Dip switch functions, Timer, Radio – Controlled Products Systems Group AOMSL1501HPDC User Manual
Page 25: Fail sf/sc, Pass, Slave, Auto open, Open l/r

24
DIP SWITCH FUNCTIONS
TIMER
TIMER switch “ON” activates the TIMER. See page 21
for details
.
RADIO
RADIO switch “ON” allows the radio receiver to override
the timer. See page 21 for details.
OSC
OSC switch “ON” allows the radio receiver to stop and
reverse the gate in any direction. During a cycle the first
signal stops gate, a second signal reverses gate.
FAIL SF/SC
This is to set the operator as fail-safe or fail secure.
ON for Fail-safe: on power failure,
board will monitor battery voltage to make sure gate opens before battery drains out
completely.
OFF for Fail-secure: on power failure gate will run until battery is low and
stay close.
1-PASS
This is a true one pass
, anti-tailgating feature. This feature may only be used with safety
loops. With this switch in the “
ON” position, the gate will open until one car passes the
safety loops then it will stop and close. If a second car pulls on the loop the gate will stop
the car must then back off the loop before the gate will close.
SLAVE
This feature is used on master/slave setups. Set slave switch “
ON” on slave machine, all
other switches “
OFF”. Set slave switch to the “OFF” position on master machine. Set
other function switches on master machine as desired. See page
17 for more details on
master/slave connections and settings.
AUTO OPEN
This feature is to automatic open the gate on power interruption. It is a very particular
feature used in areas where the fire department requires the gate to open automatically
after a power outage. Set this dip switch “ON” when this feature is desire.
OPEN L/R
This feature is to set the direction the operator will open. See page 8 for details.
OFF ON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
--
--
--
--
--
--
--
--
--
--
--
-O
P
E
N
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
-O
P
E
N
--
--
--
--
--
--
--
--
--
--
--
--
TIMER
RADIO
OSC
FAIL SF/SC
1-PASS
SLAVE
AUTO OPEN
OPEN L/R