DIP SWITCH FUNCTIONS

TIMER

TIMER switch “ON” activates the TIMER. See page 21
for details

.

RADIO

RADIO switch “ON” allows the radio receiver to override
the timer. See page 21 for details.

OSC

OSC switch “ON” allows the radio receiver to stop and
reverse the gate in any direction. During a cycle the first
signal stops gate, a second signal reverses gate.

FAIL SF/SC

This is to set the operator as fail-safe or fail secure.

ON for Fail-safe: on power failure,

board will monitor battery voltage to make sure gate opens before battery drains out
completely.

OFF for Fail-secure: on power failure gate will run until battery is low and

stay close.

1-PASS

This is a true one pass

, anti-tailgating feature. This feature may only be used with safety

loops. With this switch in the “

ON” position, the gate will open until one car passes the

safety loops then it will stop and close. If a second car pulls on the loop the gate will stop
the car must then back off the loop before the gate will close.

SLAVE

This feature is used on master/slave setups. Set slave switch “

ON” on slave machine, all

other switches “

OFF”. Set slave switch to the “OFF” position on master machine. Set

other function switches on master machine as desired. See page

17 for more details on

master/slave connections and settings.

AUTO OPEN

This feature is to automatic open the gate on power interruption. It is a very particular
feature used in areas where the fire department requires the gate to open automatically
after a power outage. Set this dip switch “ON” when this feature is desire.

OPEN L/R

This feature is to set the direction the operator will open. See page 8 for details.