22

22 - APOLLO GATE OPENER TROUBLESHOOTING

POSSIBLE SOLUTION

Check that power to the operator is turned ON

Check terminal block wiring for loose or broken wires

Check for 115 VAC at source. If voltage measures OK, check the terminal block

Check the fuse

Check the UL/Edge input on the gate controller

Adjust Force Settings

Check the input LEDs. Any ON will hold the gate open and indicates a problem with a keying device

Check the secondary safety devices. Any activated safety device will hold the gate open and indicates a
problem with the safety device

Check the loop detectors. Any activated safety device can hold the gate open and indicates a problem with
the loop detector or ground loop

Check if backup system is set to open gate automatically or requires an input to open

Check the batteries for proper voltage. Replace if necessary

Clear any obstructions from the path of the gate. Press RESET to clear (or hard reset button)

Check accessory inputs and clear then as necessary

SYMPTOM(S)

Operator will not Power On.
Power LED is OFF

Gate opens a short distance, then
stops and reverses

Gate opens but will not close

Battery backup system will not open
gate upon AC power outage

Hard Shutdown (2 back to back
obstructions) LED blinking, Buzzer
sounds for 5 minutes

Gate opens by itself

Table 3

23 - PROGRAMMING QUICKSTART

23.1 - Learning the gate

1. Install electrical power to the gate opener unit.

2. Install all gate accessories such as Photo-Eye’s, Sensors, Loops and

other safety devices.

3. Turn on the electrical power to the unit.

4. Using the MANUAL RELEASE HANDLE, disengage the drive motor.

5. Move the gate manually (with your hands) to ensure that the gate travels

to the fully open and fully closed positions with no binding or problems.
Gate should move freely.

6. Using the MANUAL RELEASE HANDLE, re-engage the drive system and

stow the handle.

7. Using the open button on the front of the Control board, hold the button

down until the gate reaches the fully open position.

8. Adjust the Open Limit Switch until the GREEN light illuminates on the

EQNMSNESGDBNMSQNKAN@QC 3GD%4++8./$-KHLHSRVHSBGHRMNVRDS

9. Using the CLOSE button on the front of the Control Board, hold the but-

ton down until the gate reaches the fully closed position.

10. Adjust the CLOSED Limit Switch until the RED light illuminates on the

front of the control board. The fully CLOSED limit switch is now set.

11. The control board is already in the “LEARNING MODE” when shipped. (If

not in LEARNING MODE see section 26.3) Press “OK” to allow the con-
trol board to scan for attached items, such as sensors, photo-eye’s and
other safety devices.

12. The gate will open partially, then stop. This is being done, so that the

control board can sense the type and operational condition of the drive
motor. The gate will then run to the closing limit, so that it can properly
sense where it is located.

13. The control board will then OPEN the gate slowly to establish travel and

limits.

14. Once the gate reaches the fully OPENED limit switch, the control board

will now increase gate travel speed to the highest speed allotted, and will
now travel to the fully CLOSED position at full speed.

15. The gate opener is now programmed for basic usage.

23.2 - Gate direction reversal

WARNING: GATE DIRECTION REVERSAL CAN ONLY BE ACCOM-
PLISHED IN LEARNING MODE

If for some reason, the installer were to install the opener on the opposite
side of the gate from which the unit is programmed, and when you press the
“OPEN” button, the gate actually CLOSES, the installer will need to REVERSE
the direction of travel to match the buttons on the control board.

Press “OPEN” and note if the gate actually opens. If it does not, and instead is
traveling in a CLOSING direction follow the below steps to correct:

1. Press FUNCTION

2. Scroll through the options to reach “ADVANCED SETTINGS”

3. Press ENTER

4. Scroll through selection to reach “DIRECTION OF MOTOR”

5. Press ENTER

6. The direction arrows on the display begin to blink

7. Choose the appropriate direction of travel

8./QDRR#(2/+ 8SNQDSTQMSNSGD, (-,$-4

9. Press OPEN to verify that the gate now OPENS

If not in learning mode, follow the below listed steps.

23.3 - Putting the controller into learning mode

Steps on how to place the Apollo 1050 control board into learning mode.

1. Press Function

2. Press OK

3. Select Slide

4. Select weight of gate

5. Press Enter

Unit should now be in LEARNING MODE

This manual is related to the following products: