beautypg.com

Controlled Products Systems Group 8300SL User Manual

Page 13

background image

11

O-View Software Suite. This unit, when matched with the OVIEW Bluetooth or
GSM modules, enables remote control and management of the gate control-
ler. Remote control functions include all programming functions that are avail-
able at the front panel LCD on the control board as well as software updates.

OVBT: Bluetooth module for OVIEW and the “O-View Software Suite” appli-
cation for PC, PDA, or Smartphone for localized wireless control of the gate
controller.

OVBTGSM: GSM module that plugs into the OVIEW and provides cellular
phone access through the “O-View Software Suite” application for PC, PDA,
or Smartphone, for wireless local, national, and international controller of the
gate controller.

O-VIEW Software Suite: Provides desktop or Smartphone level control of
SGDF@SDBNMSQNKKDQ .SGDQADMDjSRHMBKTCDRNESV@QDTOC@SDRSG@SB@MADL@CD
wirelessly as new versions of software are made available.

BLUEBUS ACCESSORIES

MOTB: Moon Touch programmable keypad with secure codes (up to 9 digits
per code if required) to control gate opening and closing. Connects to the
2-wire BlueBUS connector with inexpensive unshielded twisted-pair wire.

MOMB: Proximity card access control with capacity for up to 255 MOCARD
or MOCARDP transponder cards. Connects to the 2-wire BlueBUS connec-
tor with inexpensive unshielded twisted-pair wire.

FT210B: Photocell transmitter and receiver pair that connects to the 2-wire
BlueBUS connector with inexpensive unshielded twisted-pair wire and is a
MNMBNMS@BSRDMRNQENQDMSQ@OLDMSOQNSDBSHNM@RRODBHjDCHM4+2DBSHNM
31.1 “General Entrapment Protection Provisions”.

MASTER/SLAVE

The gate operator includes a two-pin connector designed to link two sepa-
Q@SDF@SDNODQ@SNQRSNFDSGDQ@R@,@RSDQ2K@UDO@HQ 3GD,@RSDQ2K@UDBNMjF-
uration is enabled by connecting two gate operators with simple, unshielded
twisted-pair wire (Max.100 ft.). All entrapment sensors, switch inputs, receiver
controls, and outputs must be wired to the gate operator designated as the
f,@RSDQt 3GDENKKNVHMFOQNBDCTQDNTSKHMDRSGDOQNBDRRENQBNMjFTQHMFSGD
Master/Slave pair.

/DQENQLSGDf+D@QMtOQNBDRRSNBNMjFTQDNODM@MCBKNRDKHLHSRVHSGSGDF@SD
for each operator. See the “Programming Quick Start” procedures in this
manual for a description of the gate learning process.

On the Master operator, select Function -> Adv. Settings -> Remote Mst. Slv.
Then select On -> Master. The red LED associated with the Master/Slave
connector will illuminate.

On the Slave operator, select Function -> Adv. Settings -> Remote Mst. Slv.
Then select On -> Slave. The red LED associated with the Master/Slave con-
nector will illuminate.

3GD,@RSDQ2K@UDO@HQHRMNVBNMjFTQDC 3GD2K@UDF@SDNODQ@SNQVHKKODQENQL
identical open/close/stop functions in tandem with the Master gate operator.

8.4 - Programming the plug-in receiver and remote controls

SMXI/A Plugin Receiver: The SMXI/A 433Plug-In Receiver provides up
SNBG@MMDKRENQRODBHjBBNMSQNKNEHMCHUHCT@KF@SDETMBSHNMR 3GDQDBDHUDQ
includes built-in programming functions for adding or removing Nice FloR/A
wireless remote controls to/from a gate installation. The following procedures
detail the steps to assign a remote control, add a new remote control, delete a
single remote control, or remove all remote controls from the receiver memory.

Programming the FloR/A 2-Button or 4-Button Remote Control with
the SMXI/A Plug-In Receiver.
These procedures apply to the FloR/A wireless remote control. These pro-
cedures assign factory default controls automatically to the remote control.

1. Have a functioning Nice FloR/A 2-button or 4-button remote control with a

battery installed prior to programming the remote control.

2. Press and hold the button on the side of the SMXI/A receiver until the led

illuminates green on the SMXI/A receiver, then release the button.

3. Within 10 seconds, press and hold any key on the FloR/A remote control

until the led in the SMXI/A receiver blinks green 3 times, indicating that the
FloR/A is programmed to control the receiver.

4. After the led on the SMXI/A receiver blinks green 3 times, another 10 sec-

ond interval is started to program another FloR/A remote control if desired.

Repeat step 3 to program the additional FloR/A remote control. Step 3 may
be repeated as many times as necessary to program all available FloR/A
remote controls.

5. Verify that the FloR/A remote control(s) can control the gate by pressing

one or more buttons individually on the remote control(s).

Wirelessly add new remote control to the SMXI/A Plug-In Receiver

A FloR/A remote control that has been programmed to control a SMXI/A
receiver may be used to create other FloR/A remote controls for the same
receiver. This procedure needs to be performed within 10 to 20m (30 to 60
feet) of the SMXI/A receiver, but the SMXI/A receiver does not need to be
physically accessed.

1. Press and hold any button on the un-programmed FloR/A remote control

for at least 5 seconds, then release the button, taking note of the button
that was pressed.

2. Press the same button on the programmed FloR/A remote control three

times.

3. Press the same button in step 1 on the un-programmed FloR/A remote

control and release.

4. It is recommended to test the new copy of the FloR/A remote control with

the assigned gate controller.

NOTE: This procedure will affect all SMXI/A receivers within radio

range.


Deleting a Single FloR/A Remote Control from the SMXI/A Plug-In
Receiver Memory

A FloR/A remote control that has been programmed to control a SMXI/A
receiver may be removed from the SMXI/A receiver memory without affecting
other assigned remote controls. This procedure needs to be performed at the
SMXI/A Plug-In Receiver with the affected FloR/A remote control.

1. Press and hold the button on the side of the SMXI/A receiver until the led

on the SMXI/A receiver illuminates green and keep the button pressed. The
led will illuminate after approximately 4 seconds.

2. Press and hold any button on the FloR/A remote control until the led on the

2,7( QDBDHUDQAKHMJRFQDDMk@RGDR

3. Release the button on the side of the SMXI/A receiver.

4. It is recommended to verify that the de-programmed FloR/A remote control

no longer controls the gate.

Deleting All FloR/A Remote Controls from the SMXI/A Plug-In Receiver
Memory.

All programmed remote controls may be removed from the SMXI/A plug in
receiver memory. This procedures need to be performed at the gate controller.

1. Press and hold the button on the side of the SMXI/A receiver until the led

on the SMXI/A receiver illuminates green and keep the button pressed.

2. Watch the led and on the receiver and verify the following sequence in the

led.

3. Within 4 seconds after pressing the button (approx.) the green led illumi-

nates.

4. Within 8 seconds after pressing the button (approx.) the green led turns off.

5. With 12 second after pressing the button (approx.) the green led starts

k@RGHMF

6."NTMSSGDFQDDMKDCk@RGDRNMSGD2,7( QDBDHUDQ .M$7 "3+8 the 5

TH

k@RGQDKD@RDSGDATSSNMNMSGD2,7( QDBDHUDQ

7. It is recommended to test the FloR/A remote controls, if available, with

SMXI/A plug in receiver to verify that it no longer affects the gate controller.