11.5 - Function (Continued)

Advance Settings:

The following settings are available for customizing the gate operator as required by the custom-
er’s installation requirements:
x Set Language (English, Spanish, Italian)
x Set clock 12H/24H

x Set LCD Contrast
x Direction of the Motor (only selectable in learning mode)

x Auto Close Opt. (ON - Gate only closes when at open limit, OFF - Gate auto-closes from any

open position)

x Exit Opt. (ON - Free Exit always opens gate, OFF - Free Exit doesn't open gate if stopped

while opening)

x Set Anti-tailgate (Closes gate immediately after vehicle has cleared safety sensors)
x Phototest (activates monitoring feature for BlueBus photoeyes)

x Select inputs LOOP or PHOTO
x Select UL/EDGE input type (NO, NC, Analog)

x Select Master / Slave Motor1 or Motor2
x Activate link for remote Master/Slave (Enables control of an additional gate operator board -

Not Applicable in this installation)

x Power Fail Open (Opens gate automatically on batter backup power if main AC power input

loss is detected) (Not Applicable in this installation)

x Motor 12V (Forces motor control voltage to +12VDC even if the supply voltage varies from

+9.5VDC up to +35VDC)

x Set Virtual Encoder (Used for motors without built-in encoders)

Default: This setting gives the installer/user the option of returning some or all
settings of the gate operator to the original factory settings:
• System settings
• Radio Channel settings
• Event settings
• Charger settings

ESC: Exit the FUNCTION menu.