2 - 3500ETL-1K/3600ETL-1K Operator Installation (Continued)
STEP 9. Push the arms assembly up against the gate in the closed position. Make sure that the
primary arm is locked into the stop tab on the secondary arm. Tack weld or c-clamp the gate
bracket to the gate. Permanent welds or bolt attachment should be completed once limits are
set.
2.4 - Gate Bracket Installation
STEP 8: Install the gate
bracket to the adjustable
arm using the 1/2” x 2-1/2”
hex bolt, washers, and
lock nut.
Figure 10: Connection of the gate bracket to the adjustable arm
Figure 11: Connection of the gate bracket to the gate
Figure 12: 3500 Terminal Block Wiring
STEP 10. Wire the Harness to the
operator terminal block as shown
in Figure 12.
INTERNAL MOTOR WIRING
Harness to Control Board
ORANGE (Open)
WHITE (Close)
GREEN (Common)
RED (Motor Lead)
Black (Motor Lead)