2 - 3500ETL-1K/3600ETL-1K OPERATOR INSTALLATION (Continued)

5. Adjust the Collar Open (See Figure 16) until the GREEN light illuminates on the front of the con-

trol board (See Figure 17). The FULLY OPEN limit switch is now set.

2.6 - Learning and Limit switch adjustment (Continued)

Figure 17: Green Open LED

6. Using the CLOSE button on the front of the Control Board, hold the button down until the gate

reaches the fully intended closed position.

7. Adjust the Magnet Collar Close (See Figure 16) until the RED light illuminates on the front of the

control board (See Figure 18). The fully CLOSED limit switch is now set.