Echnical, 412 c – Controlled Products Systems Group 104470 User Manual
Page 4

Page 4
January, 200 4
412 O pe rator And
455 D Control Panel I nst allatio n M anual
T
ECHNICAL
D
ATA
T
HE
412 C
OMPACT
O
PERATOR
Parameter
Measure
Voltage required
1
, VAC
115, +/–10%, 50-60 Hz
230, +6 or -10%, 50-60 Hz
Duty type
Residential duty
Maximum duty cycle
2
18 cycles/hr
30 cycles/hr
Maximum leaf length, ft (m)
14 (4.3)
Maximum leaf swing, deg
110
Thrust and traction
3
, ft-lb
(Nm)
0-294 (0-400)
0-235 (0-320)
Stroke, in. (cm)
11 3/8 (29)
Rod speed
4
, in./sec (cm/
sec)
3/4 (1.9)
5/8 (1.6)
Thermal cut out, deg F (deg
C)
284 (140)
Operator dimensions,
l ´ w ´ h, in. (cm)
39 5/16 ´ 3 3/4 ´ 7 9/16
(99.8 ´ 9.5 ´ 19.2)
Operator weight, lb (kg)
14.3 (6.5)
Current draw, A
5
2
Maximum amperage draw
for accessories, mA
800 mA
800 mA
1) While the 412 Operator is capable of 18 or 30 cycles/hr, as a residential-duty operator it is not designed for
such continuous, sustained operation.