Field connections, Local ptt connections, Ocal – CTI Products OTAL On-the-Air Driver Assembly User Manual
Page 9: Onnections, Ield

CTI Products, Inc.
OTAL Driver Assembly User Guide
F
IELD
C
ONNECTIONS
L
OCAL
PTT
C
ONNECTIONS
Local PTT signals are connected to J1 of the OTAL Driver PCB. (PTT inputs are not required if COR Only
OTAL Logic is used.)
Local PTT signals shall be either:
Isolated Form A Relay Contacts (or opto-isolated relay outputs)
closed when PTT signal is present.
Logic Outputs - Negative Ground, Active Low when PTT is active.
They must be capable of:
Up to +20 VDC Open Circuit
Sinking a minimum of 30 mA when active
Maximum of 0.2 V when active
Signals must not drive other equipment.
The Local PTT signals appear on the first 8 pairs of J1 as follows:
OTAL J1
Wire Color
Signal
1 Blu/Wht
PTT
1A
26 Wht/Blu
Gnd
1A
2 Org/Wht
PTT
2A
27 Wht/Org
Gnd
2A
3 Grn/Wht
PTT
3A
28 Wht/Grn
Gnd
3A
4 Brn/Wht
PTT
4A
29 Wht/Brn
Gnd
4A
5 Slt/Wht
PTT
5A
30 Wht/Slt
Gnd
5A
6 Blu/Red
PTT
6A
31 Red/Blu
Gnd
6A
7 Org/Red
PTT
7A
32 Red/Org
Gnd
7A
8 Grn/Red
PTT
8A
33 Red/Grn
Gnd
8A
(The “A” suffix on the PTT signals indicates the Local PTT.)
The ground signals are tied together on the OTAL Driver board. It is preferred that the PTT signals be wired to
J1 as pairs, with separate grounds.
Field
Connections
9