Remote ptt cib connections, Remote cor cib connections, Emote – CTI Products OTAL On-the-Air Driver Assembly User Manual
Page 10: Onnections

CTI Products, Inc.
OTAL Driver Assembly User Guide
R
EMOTE
PTT
CIB
C
ONNECTIONS
Remote PTT signals are connected to J1 on a remote CIB. (See Figure 1.) PTT inputs are not required if COR
Only OTAL Logic is used.
Remote PTT signals shall be either:
Isolated Form A Relay Contacts (or opto-isolated relay outputs)
closed when PTT signal is present.
Logic Outputs - Negative Ground, Active Low when PTT is active.
They must be capable of:
Up to +20 VDC Open Circuit
Sinking a minimum of 30 mA when active
Maximum of 0.2 V when active
Signals must not drive other equipment.
The Remote PTT signals appear on the following pins of J1 of the remote PTT CIB module as follows:
Remote PTT CIB J1
Wire Color
CIB Function
OTAL System Function
1 Blu/Wht
Ground
Ground-Common
22
Org/Vio
Rx 1
PTT 1B input
47
Vio/Org
Rx 2
PTT 2B input
16
Blu/Yel
Rx 3
PTT 3B input
41
Yel/Blu
Rx 4
PTT 4B input
10
Slt/Red
Rx 5
PTT 5B input
35
Red/Slt
Rx 6
PTT 6B input
4
Brn/Wht
Rx 7
PTT 7B input
29
Wht/Brn
Rx 8
PTT 8B input
The “B” suffix on the PTT signals indicates the Remote PTT.
R
EMOTE
COR
CIB
C
ONNECTIONS
The Remote COR signals are connected to J1 on a remote CIB. (See Figure 1.)
Remote COR signals shall be either:
Isolated Form A Relay Contacts (or opto-isolated relay outputs)
closed when a carrier is detected.
Logic Outputs - Negative Ground, Active Low when a carrier is active.
They must be capable of:
Up to +20 VDC Open Circuit
Sinking a minimum of 30 mA when active
Maximum of 0.2 V when active
Signals must not drive other equipment.
Field
Connections
10