5 general specifications, 6 physical specifications, 7 environmental requirements – Cleveland Motion Controls ULTRA ISC CARTRIDGE TRANSDUCER REV AA User Manual
Page 11
![background image](/manuals/333971/11/background.png)
MAN-70430-0
R
EV
AA
U
LTRA
S
ERIES
S
TATIONARY
S
HAFT
T
RANSDUCER
T
ECHNICAL
M
ANUAL
1.5 General Specifications
Item
Specification
Comments
Input Supply
Power Supply Requirements
21.6-26.4 VDC @ 50mA
Basic Isolated Amplifier
Load Cell (Transducer)
Transducer Excitation (Vexc)
3.0 VDC FIXED
Internally supplied.
Amplifier
Calibration Range
Min. 0.9 - Max. 9
Multi-turn Gain adjustment provided.
Zero Adjustment
Output Zero Preset at CMC – Accessible
by user if absolutely necessary
0V=Zero force on beam
Span (Gain) Adjustment
Preset at CMC – Accessible by user if
absolutely necessary
Adjustments provided
Amplifier Output Signal
+/-10 VDC @ 2 mA
+/-10 is undamped signal
Isolation
Isolation
+/- 50 V max.
output circuit potential not to exceed
50 V from protective earth potential
1.6 Physical Specifications
Item
Specification
Comments
Enclosure Type
Integrated Signal Conditioning mountable
with special adjustments accessible from
the surface. Remove sticker or screw to
access the setup potentiometers.
Aluminum enclosure just behind the
M12 connector.
Enclosure Size
Base: 26 mm wide by 26 mm high
Length:43 mm
1.0 inches (width) by 1.0 inches
(height) 1.7 inches (depth)
Weight – Basic Amplifier
50 Grams
2.5 ounces
Connector
4 Pin M12 Quick-Connect
M12 Quick-Connect 4 Pin, DC Keyed
1.7 Environmental Requirements
Requirement
Description
Enclosure
IP50
NEMA 1
Operating temperature
0 to 70 degrees C
32 to 158 degrees F
Humidity
Non-condensing
85% at 55 degrees C
85% at 132 degrees F
Altitude
1000 meters
3300 feet
Atmosphere
Non-flammable, non-corrosive and dust free
Storage temperature range
-30 to 90 degrees C
-22 to 194 degrees F
Transport temperature range
-40 to 80 degrees C
-40 to 176 degrees F
3