INSTEON ToggleLinc Relay (2466SW) Manual User Manual

Page 17

background image

Page 17 of 18 Rev: 1/21/2014 7:34 AM

controller.

interfering with the reception
of powerline signal.

Install additional INSTEON devices to boost
the INSTEON signal.

Increase the X10 signal strength with an
INSTEON-compatible X10 booster to
overcome the power line noise.

Remove the X10 address from the button on
your INSTEON controller so it doesn’t send
both INSTEON and X10 commands.

When I press the toggle
on ToggleLinc, it takes a
long time for other
INSTEON responders to
respond.

You may have removed an
INSTEON device that your
ToggleLinc is trying to
operate. ToggleLinc is retrying
the missing INSTEON device.

If the INSTEON device is still available, unlink it
from ToggleLinc. See

Removing

ToggleLinc

Relay as an INSTEON Responder.

Perform a factory reset. See

Factory

Reset.

ToggleLinc doesn't
respond to X10 address
A1 when I first set it up.

Unlike previous X10-only
products, ToggleLinc does not
have an X10 address set up at
the factory.

Set up an X10 address. See

Adding an X10

Address.

ToggleLinc has
unexpectedly stopped
responding.

A surge or excessive noise on
the powerline may have
glitched it.

Pull the Set button on ToggleLinc all the way
out to create an air gap, wait 10 seconds, then
push it back in until it’s flush with the trim frame
(don't push it all the way in).

If the above doesn't work, perform a factory
reset. See

Factory Reset.

ToggleLinc can turn off
my responder, but
nothing happens when I
send an ON command
from ToggleLinc.

Your responder may be linked
at its off state.

Relink your responder to ToggleLinc, while the
responding device is on.

My controller can turn off
ToggleLinc, but
ToggleLinc does not turn
on when I send an ON
command from my
controller.

ToggleLinc may be linked at
its off state.

Relink ToggleLinc to your controller, while the
load is on.

If you have tried these solutions, reviewed this Owner's Manual, and still cannot resolve an issue you are

having with ToggleLinc Relay, please call the INSTEON Support Line at 1-800-762-7845.