beautypg.com

INSTEON SwitchLinc Relay (2476S) Manual User Manual

Page 19

background image

Page 19 of 21 Rev: 1/21/2014 7:15 AM

both INSTEON and X10 commands

My light only turns off
when I tap the paddle
top on SwitchLinc, but I
can brighten and dim it

You may have removed an
INSTEON device that your
SwitchLinc is trying to operate
SwitchLinc is retrying the
missing INSTEON device

If the INSTEON device is still available, unlink it
from SwitchLinc. See Removing SwitchLinc as
an INSTEON Controller
.

Perform a factory reset. See Factory Reset.

When I press the paddle
on SwitchLinc, it takes a
long time for other
INSTEON responders to
respond

You may have removed an
INSTEON device that your
SwitchLinc is trying to operate.
SwitchLinc is retrying the
missing INSTEON device

If the INSTEON device is still available, unlink it
from SwitchLinc. See

Removing

SwitchLinc

Relay as an INSTEON Responder.

Perform a factory reset. See

Factory

Reset.

SwitchLinc doesn't
respond to X10 address
A1 when I first set it up

Unlike previous X10-only
products, SwitchLinc does not
have an X10 address set up at
the factory

Set up an X10 address. See Adding an X10
Address
.

The load is buzzing
when on or dim

The dimming component
inside SwitchLinc "chops" the
powerline sine wave to reduce
the power

The buld filaments are vibrating. Use rough-
service, 130V or appliance-grade bulbs to
reduce the noise.

Run SwitchLinc in “full-on” mode or switch to a
non-dimming SwitchLinc On/Off Relay.

SwitchLinc is locked up

A surge or excessive noise on
the powerline may have
glitched it

Pull the Set button on SwitchLinc all the way
out to create an air gap, wait 10 seconds, then
push it back in until it’s flush with the trim frame
(don't push it all the way in).

If the above doesn't work, perform a factory
reset. See

Factory

Reset.

SwitchLinc is getting
warm to the touch

It is normal for wall dimmers to
feel warm, but not hot

SwitchLinc Dimmer will dissipate about 1W per
100W controlled. Using metal wall boxes,
removing insulation around the box or
controlling a smaller load can lessen the heat.

SwitchLinc can turn off
my responder, but
nothing happens when I
send an ON command
from SwitchLinc

Your responder may be linked
at its off state

Relink your responder to SwitchLinc, while the
responding device is on

My controller can turn off
SwitchLinc, but
SwitchLinc does not turn
on when I send an ON
command from my
controller

SwitchLinc may be linked at its
off state

Relink SwitchLinc to your controller, while the
load is on

After wiring in
SwitchLinc, the unit lets
out a continuous beep

SwitchLinc is issuing an error
beep because the unit is wired
incorrectly

Turn off the circuit breaker and try reinstalling
SwitchLinc. If you are still experiencing an error
beep, consult an electrician to help you install
SwitchLinc.

SwitchLinc trips the Arc
Fault Circuit Interrupter
(AFCI)

The AFCI might be too
sensitive

Replace your AFCI with a less sensitive brand
or model from a hardware store with a
customer-friendly return policy. SwitchLinc
modules do not trip when used with the
following AFCI models:

This manual is related to the following products: