PTX-3 UHF Digital Hybrid IFB Transmitter

1 - 1 6

SYMPTOM

POSSIBLE CAUSE

Display Dead

1. External power supply

disconnected or inadequate.

2. The External DC power input is

protected by an auto-reset
polyfuse. Disconnect power and
wait about 1 minute for the fuse to
reset.

No Transmitter Modulation

1. Audio input gain setting turned all

the way down.

2. Sound source off or malfunctioning.
3. Input cable damaged or miswired.

No Received Signal

1. Transmitter not turned on.
2. Receiver antenna missing or

improperly positioned (the PRC-2
headset cable is the antenna).

3. Transmitter and receiver not on

same frequency. Check on
transmitter and receiver.

4. Operating range is too great.
5. Transmitter antenna not

connected.

6. Transmitter switch in the TUNE

position. Switch to XMIT mode.

No Sound (or Low Sound
Level); and Receiver is
powered on

1. Receiver output level set too low.
2. Receiver earphone cable is

defective or miswired.

3. Sound system or transmitter input

is turned down.

Distorted Sound

1. Transmitter gain (audio level) is far

too high. Check audio level meter
on transmitter as it is being used
(refer to Installation & Operation
section for details on gain
adjustment).

2. Receiver output may be

mismatched with the headset or
earphone. Adjust output level on
receiver to the correct level for the
headset or earphone.

3. Excessive wind noise or breath

“pops”. Reposition microphone
and/or use a larger windscreen.