beautypg.com

Clear-Com EF-701M User Manual

Page 42

background image

3 - 4

E F - 7 0 1 M I N T E R F A C E

Data Troubleshooting Tips

Symptom

Cause

Solution

Data LED is off even though
units are connected at each
end.

1. Problem in the wiring from the
DB-15 to the modem or problem
with the transmission medium.
2. Baud rate or other modem
requirements not compatible with
EF-701M.
3. The EF-701M units are set to
different baud rates.
4. One EF-701M is set to Matrix
Direct Mode when connected to
another EF-701M.

1. Adjust wiring.

2. Adjust EF-701M units to match.

3. Adjust EF-701M units to match.

Data LED blinks rapidly.

EF-701M is receiving a "break" signal
from the RS-422. Typically a power
loss on the modem at the far end
causes this.

Check modem power connections.