Installation, Unpacking the rcs-2700, Wiring overview – Clear-Com RCS-2700 User Manual
Page 21: Installation -1, Unpacking the rcs-2700 -1 wiring overview -1
R C S - 2 7 0 0 S O U R C E A S S I G N M E N T P A N E L
2 - 1
INSTALLATION
UNPACKING THE RCS-2700
When you unpack the RCS-2700 Source Assignment Panel, you will find the
following items:
• RCS-2700 unit
• RCS-2700 manual
• 31 6-terminal Euro-block connectors
The Euro-block connectors press on to the rear-panel pins of the RCS-2700 unit.
They are used to wire the unit to destinations and sources. You can install the
connectors with the visible screws facing either upward or downward. However,
facing the screws upward, so that they are visible from above, allows more
flexibility in tightening the connections.
WIRING OVERVIEW
Four sets of pins on the rear panel of the RCS-2700 connect the unit to source
channels, destinations, expansion RCS-2700 units, and power.
An overview of the wiring is given below, with more detailed explanations and
diagrams following later in the chapter.
Figure 2-1: Four Sets of Connection Pins on the Rear Panel of an RCS-2700 Unit
13
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
DESTINATION POWER
1 2 3 4 5 6 7 8
SOURCE POWER
SCE
RCS PWR
13
DESTINATIONS
14
15
16
17
18
19
20
21
22
23
24
1
DESTINATIONS
2
3
4
5
6
7
8
9
10
11
12
1
SOURCES
2
3
4
5
6
7
8
SOURCE EXPANSIONS
14
15
16
17
18
19
20
21
22
23
24
1
SOURCE EXPANSIONS
2
3
4
5
6
7
8
9
10
11
12
MTX
CONT
DATA
LINKS
PC SERIAL
PORT
RCU-67
M
4
2
A
1
3
5
B
ADDRESS
1 2 3
8
4 5 6 7
TERMINATION
SWITCHES
ON
OFF
CODE RESET
1
2
3
4
Power Patch Panel
Source Connections (Power and Audio)
Destination Connections (Power and Audio)
Source-8 Connection Points
Tie Together or Connect to Expansion Units
• You connect the
RCS-2700 unit to source
channels, destinations,
expansion RCS-2700
units, and power.
2