Software - SYSTEM CONFIGURATION
Cap 2
For each entrance, select an output that this
supplementary digital device
will act on; also the related box must be
ticked if the device is type NC
(normally closed)
In the inputs area of the REM n board
you must program the supplementary
command and control
devices (e.g. safety buttons, sensitive
footboards, alarms etc.) that will be
connected to the REM and act on any
one of the RBM84 and REM outputs.
In the pull-down menu, there appear, in addition to the normal exits defined in Assign Exit Name,
exits/functions
defined as “Block”, “Entry Alarm”, “Reset Alarm “ and “Entry” + “Exit” for each
traffic-light control;
The digital input/output association is independent of the physical position of the latter on RBM84 or
REM;
RBM84 -Software
Confi guring the digital entrances of the REMs
Assign the digital devices to an output (REM)
to adjourn
Caution! at the end of every group of operations, you must update to make the changes effective