Available versions, Technical data, Conditions of use – Burkert Type 8035 User Manual
Page 9: Conformity to standards and directives

TOTAL :SE35/8035 COIL 9V
IP65
S/N 1439
00423921
W43MA
M
ade in Franc
e
1
2
4
5
7
8
3
6
Fig. 2: Name plate of the
8035
1.
Type of the device
2.
Specification of the flow sensor
3.
Power supply
4.
Manufacturing code
5.
Conformity logo
6.
Protection rating
7.
Serial number
8.
Order code
5.4.
Available versions
• The flowmeter-totalizer type 8035 is made up of an SE35 elec-
tronic module with order code 423921 and of an S030 fitting-
sensor which has to be ordered separately.
• The flowmeter-totalizer type 8025 exists in 2 versions:
type of flow sensor
seal material
order code
short, with coil
FKM
418403
long, with coil
FKM
418405
6.
TechnicAl DATA
6.1.
conditions of use
Ambient temperature
0 to +60 °C
Air humidity
< 80%, without condensation
Height above see
level
max. 2000 m
Protection rating
IP65, cover lid screwed tight and screwed
plugs.
6.2.
conformity to standards and
directives
The device conforms to the EC directives through the following
standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• LVD: EN 61 010-1
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure: article 3§3 of the Pressure Directive 97/23/CE. Acc. to
the Pressure Directive 97/23/CE: the device can only be used in
the following cases (depending on the max. pressure, the DN of
the pipe and the fluid)
7
Technicaldata
Type 8025/8035 battery powered
English