Installation of 8025 on the s020 fitting, Description of the electronic board connections, The s030 fitting-sensor – Burkert Type 8035 User Manual
Page 16
7.2.2. installation of 8025 on the s020
fitting
→
Insert nut 3 on the fitting 5.
→
Insert the snap ring 2 into the groove 4.
→
Check that seal 6 is correctly inserted on the
flow sensor.
→
Slowly insert the device 1 into the fitting.
If the mounting is correctly done the device cannot
turn around anymore.
→
Hand lock the assembly with the nut 3.
2
1
3
4
5
6
Fig. 7: Installation of 8025 on the S020 fitting
7.2.3. installation of the se35 electronic
module on the s030 fitting-sensor
→
Insert the electronic module 2 in the
S030 fitting-sensor.
→
Secure with a 30° clockwise rotation.
→
Tighten the lateral screw 3 to lock
the electronic module with the
fitting-sensor.
1
2
3
Fig. 8: Installation of the SE35 electronic module on the S030
fitting-sensor
7.3.
Description of the electronic
board connections
Terminal block:
+ : positive supply (red wire)
- : negative supply (black wire)
Connector : branchement du
capteur de débit
Terminal block
Connector
OFF ON
Fig. 9: Electronic board
connections
14
Installation
Type 8025/8035 battery powered
English