Type 8660 control center, Technical data 11.1 electrical data, 2 mechanical data – Burkert Type 8660 User Manual
Page 34
Type 8660 Control Center
________________________________________________________
- 34 -
11.
Technical Data
11.1 Electrical Data
Operation sizes
Pin number
Operational mode
Power consumption
1,2,3 (+24 V)
ignition off (standby operation)
< 50 mA
1,2,3 (+24 V)
ignition on, motor off
< 100 mA
1,2,3 (+24 V)
ignition on, motor on
< 200 mA
1,2,3 (+24 V)
all outputs switched on
< 20 A
5 (ignition on)
maximum power consumption
< 100 mA
6 (lighting circuit)
maximum power consumption
< 100 mA
7 (illumination)
maximum power consumption
< 200 mA
Reverse polarity protection
The supply inputs of the Control Centers are permanently protected against
reverse polarity of ground and plus.
Electromagnetic compatibility EMC
Resistance to disturbances:
meets ISO/DP 7637/2
Radiation measurement:
meets DIN 40839
CE symbol
The Control Center has a CE-conformity symbol for all three variations.
11.2 Mechanical Data
Weight
0.4 kg
Storage temperature
-40...+120 ºC
Operation temperature
-25...+85 ºC
The front panel is built to withstand water spray.