beautypg.com

Type 8660 control center, 4 changing the air flow direction in za, 5 switching the defrost function on and off in za – Burkert Type 8660 User Manual

Page 22: 6 changing the temperature set point in za

background image

Type 8660 Control Center

________________________________________________________

- 22 -

With the exiting of the setting mode Day and Condition of the time-switch, or the setting mode Switch

time, the changes which have been made to the time-switch day or the switch time will be saved and

active. When at least one time-switch day is active (on), the symbol

next to the Temperature set

point knob will be illuminated.

After the supplementary heater has been switched on once by the time-switch, the condition of the

corresponding time-switch day will be changed from 'on' to the condition 'oFF'. In this way, the time-

switch can be programmed for a maximum of 7 days.

7.2.4 Changing the air flow direction in ZA

The air flow direction can be changed by adjusting the Air flow direction knob. When the knob is

pointed to the symbol for Air flow direction to windshield, Air flow direction to windshield and to driver

or Air flow direction to driver, the air flow will be conducted in the corresponding direction.

7.2.5 Switching the Defrost function on and off in ZA

The Defrost function will be switched on, when the Air flow direction knob is turned to the symbol

(Defrost). In the operational mode Ignition off, this function automatically includes the directing of the

air flow direction to the windshield and the opening of the front box valves. The Front box blower knob

and Temperature set point knob have no functions, when the Front box flaps knob is in this position.

7.2.6 Changing the temperature set point in ZA

In operational mode Ignition off, the temperature set point can be changed by adjusting the

temperature set point regulator. The front box valve will be accordingly adjusted, depending on the

setting of the temperature set point regulator.