Technical Data
Operating voltage
24 V; -15 % / +20 %
Residual ripple
2 V
ss
Current consumption
Inputs / Logic
max. 1 A
Outputs
max. 4 A (M12)
Overview
Detail drawing
Diagnostic / Status LEDs (20)
RIO
Status
U
i
Logic vol-
tage
F
S
Error
select
U
O
Output
voltage
F
N
Error
number
U
S
Sensor
voltage
33
GB
13
22
50
20
8
9
23
51
52
53
18
19
26
8
FE contact
9
FE contact
13
Type plate
18
Rotary encoder switch
(x1)
19
Rotary encoder switch
(x10)
20
Diagnostic/Status LEDs
(see detail drawing)
22
Label panel Power
23
Connection Power
26
Diagnostic and update
interface
50
Label panel RIO IN
51
Connection
RIO IN (M8)
52
Label panel RIO OUT
53
Connection
RIO OUT (M8)
34
GB
Electrical connections
Voltage supply
M12, plug 4-pin, max. 4 A
RIO incoming
M8, jack
RIO outgoing
M8, jack
Address setting
via rotary encoder switch
Address range
0 ... 49
Integrated diagnostic
interface
3-pin, (RM 2.54)
Diagnostic LEDs
2 x RIO status
2 x fault indication
3 x supply voltage
Connection table
PIN
RIO IN /
RIO OUT
Power / Supply Voltage
1
CAN_H
+24 V Output (U
o
)
2
CAN_L
+24 V Logic / Sensors (U
i
)
3
FE
GND Logic / Sensors (U
i
)
4
_
GND Output (U
o
)
35
GB
PNEUMATIC CONNECTIONS
Field bus- / Multipole- /
RIO-module
Intermediate module
(Inside)
42
44
43
45
1
3/5
82/84
12/14
Ext.
Int.
Push
Turn
42
44
43
45
47
42 Auxiliary control air
M5, D6, D4, D1/4“
43 Pilot exhaust air
M5, D6, D4, D1/4“
44 Exhaust air
G1/4“, NPT1/4“, D10
45 Compressed air supply
G1/4“, NPT1/4“, D10
47
Switching between external / internal auxiliary con-
trol air. Connector 12/14 must be closed for internal
auxiliary control air.