Burkert Type 8645 User Manual

Page 5

background image

16

GB

C) Block mounting

Proceed with block mounting as follows:

Wall:

install the block on the wall

install the FE connection on the front of the fi eld bus
module

connect the FE contacts (8) via the FE rail

connect the FE rail to FE

DIN rail:

remove the blue connection brackets between the
modules

open the DIN rail mountings

place the block onto the DIN rail by hooking in and pivot-
ing from above

tighten the DIN rail mountings

release the locking clamp

install the FE connection on the front of the fi eld bus
module

connect the DIN rail to FE

17

GB

CAUTION!

Material damage due to leakage in the system!

Open DIN rail mountings and locking bolts (modules) result
in leaks within the system.

Lock all open mountings and locks before commission-
ing!

18

GB

MOUNTING / COMMISSIONING

WARNING!

Danger from high pressure!

Serious danger of injury while working on the system.

Always switch off the power before opening the sys-
tem!
Disconnect the pressure before loosening lines and
valves.

CAUTION!

Danger when working on the system.

Non-trained personnel can cause damage to the system.

Installation and maintenance work must only be carried
out by authorised specialist personnel using appropriate
tools!
Observe the applicable accident prevention and safety
regulations for electrical devices.

19

GB

PROFIBUS

®

FIELD BUS MODULE

Technical Data

Operating voltage

24 V; -15 % / +20 %

Residual ripple

2 V

ss

Current consumption
Inputs / Logic

max. 1 A

Outputs

max. 4 A (M12)

Profi bus

®

Transmission rate

9.6 kBaud to 12 MBaud

Inductances in the

100 nH / 0.16

module

for incoming and outgoing

bus

Overview

Detail drawing

Diagnostic / Status LEDs (20)

BUS status

U

i

logic voltage

F

S

error
select

U

O

output voltage

F

N

error
number

U

S

sensor voltage