Techncial data, Electrical data – Burkert Type 6115 User Manual
Page 8
8
Techncial data
6. TECHNCIAL DATA
DANGER!
RISK OF EXPLOSION!
• Exceeding the technical data indicated on the rating plate
increases the explosion risk!
• Never exceed the technical data indicated on the rating plate!
Example
PTB-certification No.
Coil type - port size for fluid part
- coil size
Mode of protection/temperature code
Voltage (±10 %) - power rating
Ambient temperature
Serial no. of the coil /CE designation
Ident. no / date of production
Space for barcode
6.1. Electrical data
Devices suitable for individual and block assembly
Device dimensions:
Length (mm)
Width (mm)
Height (mm)
Mass (g)
18
10
49
14
Approval code:
PE40 PTB 01 ATEX 2194 X
II 2G EEx ia IIC T6
Piezoelectric actuator Type 6115
The device may be attached with or without protective circuit, as
specified.
Electrical connection:
JC18
2 impressed FEP wires, blue and brown
JF79
circular connector M8, 3-pole
JF80
Rectangular connector, 2-pole
Data on safety engineering:
Piezoelectric actuator in ignition protection type intrinsically safe EEx
ia IIC, for connection only to certified intrinsically safe circuits with
english
PTB 01 ATEX 2194 X