Disassembly, Start-up, Safety instructions – Burkert Type 0789 User Manual
Page 14

14
Start-up
The connection cable is encapsulated with the coil and
cannot be removed.
→
Attach the electrical connection.
7.4. disassembly
DanGEr!
risk of electric shock!
There is a serious risk of injury when reaching into the equipment.
• Only trained electrical engineers may work on the electrical
system.
• Before starting work, always switch off the power supply and
safeguard to prevent re-activation!
• Observe applicable accident prevention and safety regulations
for electrical equipment!
procedure:
→
Disconnect the power connection.
→
Disconnect the valve body from the pipeline.
notE!
malfunctions as a result of contamination!
• In case of new installation, remove old PTFE tape from the connec-
tions. Residues or parts of the tape must not get into the pipeline.
8. sTarT-up
8.1. safety instructions
WarnInG!
danger due to improper operation!
Improper operation may result in injuries as well as damage to the
device and the area around it.
• Before start-up, ensure that the operating personnel are familiar
with and completely understand the contents of the operating
instructions.
• In particular observe the safety instructions and intended use.
• The device may be started by adequately trained personnel only.
before commissioning, ensure that:
• The device has been correctly installed,
• The connections have been correctly made,
• The device is not damaged,
• All bolts are securely tightened.
english
PTB 03 ATEX 1030 X