3.1. Electrical data

Type

64.-....-...-.

65.-....-...-.

Temperature class

T4

T5

Type of current

universal

universal

Rated voltage

12 ... 240 V

12 ... 240 V

Rated current

0.58 ... 0.034 A

0.42 ... 0.025 A

Holding power

7 W

5 W

3.1.1. Electrical connection

Marking

Execution

Internal code

A *

Permanently installed rubber sheathed cable of
Type H05 RN-F3G0.75

none

L

** Terminal box with cable bushing M20 x
1.5, without fuse

JA02

Terminal box with threaded nipple M20 x 1.5,
without fuse

JA08

Terminal box with threaded nipple NPT 1/2,
without fuse

JA09

Terminal box with threaded nipple G 1/2, without
fuse

JA10

K ***

** Terminal box with cable bushing M20 x
1.5 and fuse

JA01

Terminal box with threaded nipple M20 x 1.5 and
fuse

JA05

Terminal box with threaded nipple NPT 1/2 and
fuse

JA06

Terminal box with threaded nipple G 1/2 and fuse

JA07

* The connecting cable of solenoid Type 6..- must be laid permanently

such that it is adequately protected from mechanical damage

** Cable bushing to separate Design Inspection Certificate
*** Fuse/contactor to separate Design Inspection Certificate

NOTES!

The minimum rated cross-section of the conductor strands is
0.75 mm

2

.