beautypg.com

Accessing the bottom inspection trap, 3 accessing the bottom inspection trap – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual

Page 59

background image

7.3

Accessing the bottom inspection trap

Have a lip gasket and a retainer ring on hand for the

inspection hatch.

1. Disconnect the mains supply.
2. Drain the calorifier.
3. Open a hot water tap.
4. Open the valve on the safety unit.
5. Set the appliance to repair position 1.
6. Check the extent of scaling in the tank and on the exchanger.

Keep the limescale on the wall of the tank: it provides effective

protection against corrosion and enhances the insulation of the

DHW tank.

Remove limescale deposits from the bottom of the tank.

Remove limescale deposits from the exchanger to guarantee its

performance.

7. Fit the unit together.

CAUTION

Each time it is opened, the lip gasket + retainer ring unit

must be replaced to guarantee tightness. Place the

positioning lug on the gasket toward the outside of the

tank.

8. After reassembly, check the tightness of the lower flange.

The screws retaining the visit trap must be tightened to

6 N·m +1/-0. Use a torque wrench.

85°

1

C

00

31

9

0-B

TWH 200E TWH 300E TWH 300EH

7. Checking and maintenance

03/02/2014 - 300026515-001-03

57