Accessing the bottom inspection trap, 3 accessing the bottom inspection trap – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual
Page 59
7.3
Accessing the bottom inspection trap
Have a lip gasket and a retainer ring on hand for the
inspection hatch.
1. Disconnect the mains supply.
2. Drain the calorifier.
3. Open a hot water tap.
4. Open the valve on the safety unit.
5. Set the appliance to repair position 1.
6. Check the extent of scaling in the tank and on the exchanger.
Keep the limescale on the wall of the tank: it provides effective
protection against corrosion and enhances the insulation of the
DHW tank.
Remove limescale deposits from the bottom of the tank.
Remove limescale deposits from the exchanger to guarantee its
performance.
7. Fit the unit together.
CAUTION
Each time it is opened, the lip gasket + retainer ring unit
must be replaced to guarantee tightness. Place the
positioning lug on the gasket toward the outside of the
tank.
8. After reassembly, check the tightness of the lower flange.
The screws retaining the visit trap must be tightened to
6 N·m +1/-0. Use a torque wrench.
85°
1
C
00
31
9
0-B
TWH 200E TWH 300E TWH 300EH
7. Checking and maintenance
03/02/2014 - 300026515-001-03
57