Heating time of the dhw tank depending on the air, Temperature, Pump depending on the air temperature – DE DIETRICH KALIKO TWH 200E - TWH 300E - TWH 300EH User Manual

Page 18

background image

Model

TWH 300 E

TWH 300 EH

TWH 200 E

Operating pressure

bar (MPa)

10

10

10

Power supply voltage

V

230

230

230

Circuit breaker

A

16

16

16

Exchanger surface

m

2

-

1.00

-

Continuous output DT = 35 K

(3)

(4)

litres per hour

-

955.6

-

Flow rate over 10 minutes with DT = 30 K

(3)

l/10 mm

-

420

-

Heating time (15-51 °C)

(1)

Hours

7

7

5

Qpr

(1)

kWh/24h

0.67

0.75

0.73

V40

(1)

litres

357

358

240

Vmax

(2)

litres

388

383

281.9

Pes

(2)

W

34

36

30

Maximum length of the air connection Diameter 160 mm

(5)

m

25

25

25

R134a refrigerant

kg

1.45

1.45

1.45

Weight (empty)

kg

105

123

92

(1) Value obtained at an air temperature of 15°C and a relative humidity of 70%. Water inlet temperature at 15°C in accordance with EN255-3.

(2) Value obtained with an air temperature of 7 and a water inlet at 10 °C, as per EN16147 based on Specification LCIE N°103-15/B:2011

(3) Domestic cold water input at 10°C - Primary inlet temperature at 80°C

(4) Output: 34.1 kW

(5) The installation of suction and backflow conduits on the heat pump lessens its performance

3.4.2.

Heating time of the DHW tank depending on
the air temperature

Scenario for complete heating of the DHW tank

A

Heating time for a set point of 51°C

B

Heating time for a set point of 62°C

Y

Heating time (Hours)

X

Air temperature (°C)

3.4.3.

Max domestic hot water set point reached
by the heat pump depending on the air
temperature

Y

Max domestic hot water temperature (°C)

X

Air temperature (°C)

0

2

4

6

8

10

12

14

16

18

20

-5

0

5

10

15

20

25

30

35

Y

X

B

A

C003447-A

C003483-B

51°

-5

0

5

7

10

X

55°

65°

Y

3. Technical description

TWH 200E TWH 300E TWH 300EH

16