APPENDIX

SPECIFICATIONS

SYSTEM

Measuring Principle

Doppler Ultrasonic.

Velocity Range

0.15 to 30 FPS (0.05 to 9 MPS); minimum calibrated span 0.15 to 5 FPS (0.05 to 2 MPS).

Accuracy

±2% full scale, over calibrated span.

Liquid Types

Liquids containing a minimum of 100 ppm of useful sonic suspended reflectors greater than 35 micron
in size, and at least 25% of the overall particle volume is larger than 100 microns. (See Product Applica-
tions page
for details.)

TRANSMITTER

Enclosure

NEMA 4X (IP 66), Polycarbonate, Stainless Steel, Brass, Plated-Steel Mounting Brackets.
7.00 H × 5.75 W × 3.88 D inches (178 H × 146 W × 99 D mm).

Power Supply

115/100/230 VAC 50/60 Hz ±15% @ 17 VA max; 12-28 VDC @ 7 Watts max.

Display

2 line × 8 character LCD, LED backlight.

Top Row: 7 segment, 0.7” (18 mm) high, numeric.

Bottom Row: 14 segment, 0.35” (9 mm) high alpha-numeric.

Flow Rate Indication: 8 digit positive, 7 digit negative max.; auto decimal, lead zero blanking.
Flow Totalizer: 8 digit positive, 7 digit negative, resettable.

Engineering Units

User configured - gal, liters, million gal, ft³, m³, acre-ft, oil barrels (42 gal), liquor barrels (31.5 gal), ft, m,
lb, kg.

Rate Interval

Seconds, minutes, hours, days.

Totalizer

Exponents from E

-2

(÷100) to E

+6

(x1,000,000).

Response Time (Flow)

User selectable; 6 to 60 seconds.

Input/Output

4-20 mA

800 Ohms max; internal or external power supply; 12-bit resolution; optically isolated.

Dual Relay

Independently configured; Form C, 200 VAC @ 0.5 A resistive; rate alarm, error alarm,

totalizer

pulse.

Rate Pulse (Two types); Both - 2,500 Hz max; 12-bit resolution.

1) 500 mVAC - 500 mVAC into 2K Ohm minimum.

2) Open Collector - Open Collector 1 A @ 100 V maximum.

Multiple Meters

Synchronization provision included - utilized for multiple meter, single pipe/manifold sys-
tem. Up to four meters may be interconnected, up to 100 feet (30 meters) apart.

Keypad

Four keys, tactile.

Ambient Conditions

-40 °F to +185 °F (-40 °C to +85 °C), 0 to 95 % relative humidity (non-condensing).

Approvals

(Std.) General safety U.S. and Canada, certified to UL 61010-1 and CSA C22.2 No. 61010-1 complies with
EMC directive 2004/108/EC.