BEI Sensors Divide-By Module User Manual
Electronic modules, Bei sensors, Divide-by module
Electronic Modules
Divide-By Module
BEI Sensors
7230 Hollister Avenue
Goleta, CA 93117
www.beisensors.com
Tel: 800-350-2727
Fax: 805-968-3154
Specification No.:09166-016
Rev 3-18-14
Electronic Modules
Divide-By Module
BEI Sensors
The Divide-By Module option provides a method to divide the effective resolution and signal
frequency of a quardrature output incremental encoder. The Divide By option is available
with the BEI Optical Isolator and Broadcaster. The module receives quardrature counts
from an incremental encoder and divides them by a predetermined integer value. The index
signal is passed through without modification. When combined with the Optical Isolator a
single encoder can be used to feed different control devices, synchronizing their outputs at
different ratios. This can lower parts count and reduce overall system costs.
This module accepts single ended or differential inputs and divides the signal by a factory set
number from 2 to 256. The resulting output signal is a reduced resolution of the input signal.
Ideal for use in machine retrofitting and for applications where a different resolution output is
needed from the same encoder source. When ordering, make sure to specify the divide-by
amount in the model number (see ordering options below).
Divide By Module Ordering information
FOR ASSISTANCE CALL 800-350-2727
SAMPLE: EM - DR1 - DB2 - 5 - 28V/V
Specifications
Power:
The optical isolator can accommodate standard operating voltages from 5 to 28 VDC. It should
never be connected directly to AC power mains. The module draws approximately 75 mA and a
green LED indicates the unit is powered. The optical isolator module does not provide power to
the encoder. Any encoders used in conjunction with this module must be connected to their own
power.
Signal:
Specifying an optical isolator module requires knowledge of three system parameters: the DC
supply voltage available in the system; the encoder output type (logic levels and driver type); and
the input signal specifications of the receiving electronics.
Output Code Format From Encoders
Dual Channel in quadrature plus index and complements. Data lines are designated A, B, Z, A/, B/,
Z/ at the module
Output Signal Type From Encoder
Differential line driver (Use Connection Instructions #1)
Single ended line driver (Use Connection Instructions #2)
Single ended open collector with pull-up resistors internal to encoder (Use Connection Instructions
#3)
Single ended, open collector (Use Connection Instructions #3)
Output Signal Voltage Level From Encoder
5 VDC (TTL, RS422 compatible, line driver)
12-15 VDC
24VDC
Frequency Response of Optical Isolator
1 MHz, maximum
Power Requirements For Optical Isolator
5-28 VDC ±5%, 75mA plus load current
Optical Isolator Output Options
28V/V Line Driver, 100mA source/sink, Vout = Vin
28V/5 Line Driver, 100mA source/sink, Vout = 5V (Derate output current to 50mA with supply
voltage > 12VDC)
28V/OC NPN Open Collector, 80mA sink
Protection Level
Supply lines protected against over voltage to 60 volts and reverse voltage
Tristate Outputs
Available as –S Special Feature
EM
DR1
TYPE:
EM = Electronic Module,
DIN Rail mount
FUNCTION
DB = Divide By
OUTPUT TERMINATION:
TB = Terminal Block
VOLTAGE/OUTPUT:
28V/V:28 V maximum, Vout=Vin
28V/5:28V maximum, Vout=5V
28V/OC:28V maximum, Vout=Open Collector
DB
TB
DIVIDE BY FACTOR:
Integer Value from 2 to 256
PACKAGE STYLE:
DR1 = 114.5 mm x 99mm x 22.5 mm
5
OUTPUT VOLTAGE FROM
ENCODER
3=2.5-3.7 V Logic
5=3.7-6.8 V Logic
15 = 11-19V Logic =
24 = 19-29V Logic =
Mechanical
Package dimensions are 114.4 mm high by 99 mm wide by 22.5 mm thick. The package
mounts to a DIN rail type EN 50 022 (35mm X 7.5mm). A length of DIN rail is supplied with
each module. The module simply snaps directly to the DIN rail and is ready to use.