Hhm5, Magnetic incremental encoders, hhm5 range – BEI Sensors HHM5 User Manual
Page 2

HHM5
MAGNETIC INCREMENTAL ENCODERS, HHM5 RANGE
BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél
: +33 (0)3 88 20 80 80
Fax
: +33 (0)3 88 20 87 87
Web :
www.beisensors.com
OUTPUT ELECTRONIC / POWER SUPPLY
2G2 electronic (100kHz)
Supply : 5Vdc 10%
Cons. without load : 40mA max
Current per channel : 40mA max
0 max (Is=20mA) : V
ol
= 0,5Vdc
1 min (Is=20mA) : V
oh
= 2,5Vdc
2G2
PG5
PG5 electronic(100kHz)
Supply : 5 to 30Vdc
Cons. without load : 40mA max
Current per channel : 40mA max
0 max (Is=20mA) : V
ol
= 0,5Vdc
1min (Is=20mA) : V
oh
= Vcc-3Vdc
Protection against short circuits and inversion of polarity for the electronic PG5
STANDARD CONNECTION
-
+
A
B
0
A/
B/
0/
Ground
G3
PVC cable,
8 wires
8230/020
WH
white
BN
brown
GN
green
YE
yellow
GY
grey
PK
pink
BU blue
RD
red
Main
shield
G6 M23 connector
1
2
3
4
5
6
7
8
Connector
body
GP
PUR cable 12
wires 8230/050
WH white +
WH/GN
white/green
BU blue
+
BN/GN
brown /
green
GY
grey
BN
brown
RD
red
PK
pink
GN
green
BK
black
General
shielding
ORDERING REFERENCE
(Contact the factory for special versions , ex: stainless steel version, connections…)
Shaft
Supply
Output stage
Signals
Resolution
Connection
Connection
orientation
G3 : PVC
cable 8
wires
GP : PUR
cable 12
wires
A020 : axial
cable 2m
R020 : radial
cable 2m
HHM5
06 :
Shaft 6mm
10 :
Shaft
10mm
2G2 : 5Vdc
TTL / RS422 output
PG5 : 5 to 30Vdc
Push-pull output
(TTL / RS422 available if
encoder supply is 5Vdc)
9 :
A, A/,
B, B/,
0, 0/
1024
max
G6 : M23
connector
A : Axial
R : Radial
Ex: HHM5_
10 //
PG5
9 //
01024 //
G3
A020
Available resolutions
: 32 64 128 256 1024
Made in FRANCE
Changes possible without further notice - Version 100909