beautypg.com

Made in france, Ibo5, Atex incremental encoders, ibo5 range – BEI Sensors IBO5 Incremental Intrinsically Safe Encoder User Manual

Page 2

background image

IBO5

BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim

F 67013 Strasbourg Cedex

Tél

: +33 (0)3 88 20 80 80

Fax

: +33 (0)3 88 20 87 87

Mail :

[email protected]

Web :

www.beisensors.com

ATEX INCREMENTAL ENCODERS, IBO5 RANGE

OUTPUT ELECTRONIC / SUPPLY - DIGITAL SIGNALS (SQUARE WAVE SIGNALS)

Supply : 4.5 to 6Vdc Consumption : 75mA max

Output RS422, 40 mA, F

max

=300kHz

Protection against short circuits

Intern capacity: 1.3µF, intern inductance: 0mH

Barrier to be used for supply:

Ui<10V, Li<750mA, Pi<1.875W

Barrier to be used for each output:

Electronic 2G2

Ui<10V, Li<200mA, Pi<0.5W


STANDARD CONNECTION

-

+

A

B

0

A/

B/

0/

Ground

G3

PVC cable 8

wires 8230/020

WH

white

BN

brown

GN

green

YE

yellow

GY

grey

PK

pink

BU

blue

RD

red

General

shielding



ORDERING REFERENCE

Shaft

Digital Signal (square)

Connection

Orientation

Electronic

Signals

Resolution

Supply

Output stage



IBO5



14 : 14mm 2 : 5Vdc

G2 : driver 5Vdc RS422

9 : A,A/,B,B/,0,0/

(0 gated A&B)

80 000

max
















G3 : PVC cable

8 wires










Example :


R020: radial
cable 2m

IB05 _

14 //

2

G2

9 // 10 000//

G3

R020


Available resolutions

: 50 60 100 120 125 127 150 180 200 240 250 256 300 314 360 375 400 500 512 600 720 750 762 768 800 927

1000 1024 1200 1250 1280 1440 1500 1800 2000 2048 2400 2500 3000 3600 4000 4096 5000

Interpolated available resolutions

: 1080 2560 2880 3072 4320 5120 5760 6000 7200 7500 8000 8192 9000 10000 10240 10800

12000 12500 12288 14400 15000 16000 16384 18000 20000 20480 24000 25000 28800 30000 32000 32768 36000 40000 40960
43200 48000 49152 50000 57600 60000 64000 65536 80000

NEVER CONNECT/DISCONNECT OR OPEN THE ENCODER WITH POWER ON IN DUST
ENVIRONMENTS
RESPECT THE MOUNTING TOLERANCES AND THE MECHANICAL RESTRICTIONS IN ORDER TO
REMAIN IN LINE WITH THE MAXIMUM SURFACE TEMPERATURE VALUE ALLOWED BY THE CLASS T4
REQUIREMENTS


LCIE 04 ATEX 6109 X /01 : CE certification of Type for the encoder :

Operating Temperature : -30°C to +70°C
The components of the device are intrinsically safe: they can be used in explosive atmospheres. The supply and output
circuits can only be connected to associated devices which are intrinsically safe and that are certified by type [ia]. These
devices must have electrical parameters that have a compatible supply with the above mentioned electronics, like BEI
barriers.


LCIE 04 ATEX 6155 X /01 : CE certification of Type for the encoder’s system (encoder associated with a BEI barrier) :

Operating temperature: barrier : -20°C to +40°C, encoder: -30°C to +70°C
The interconnecting cables have to be sufficiently protected against damage and have to be separated from the non
intrinsically safe circuits. They are described in the norm EN50020 paragraph 6.3, with the following characteristics
C=100pF/m and L=1.2µH/m, or with cables with other C and L values, With respect to the maximum authorized values:

Mines & Gases : Ca=3.9µF and L=0.4 mH

Dust : Ca=38.7µF and L=0.8mH

Made in FRANCE

Changes possible without further notice - Version 080919