IBO5
BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél
: +33 (0)3 88 20 80 80
Fax
: +33 (0)3 88 20 87 87
Web :
www.beisensors.com
ATEX INCREMENTAL ENCODERS, IBO5 RANGE
OUTPUT ELECTRONIC / SUPPLY - DIGITAL SIGNALS (SQUARE WAVE SIGNALS)
Supply : 4.5 to 6Vdc Consumption : 75mA max
Output RS422, 40 mA, F
max
=300kHz
Protection against short circuits
Intern capacity: 1.3µF, intern inductance: 0mH
Barrier to be used for supply:
Ui<10V, Li<750mA, Pi<1.875W
Barrier to be used for each output:
Electronic 2G2
Ui<10V, Li<200mA, Pi<0.5W
STANDARD CONNECTION
-
+
A
B
0
A/
B/
0/
Ground
G3
PVC cable 8
wires 8230/020
WH
white
BN
brown
GN
green
YE
yellow
GY
grey
PK
pink
BU
blue
RD
red
General
shielding
ORDERING REFERENCE
Shaft
Digital Signal (square)
Connection
Orientation
Electronic
Signals
Resolution
Supply
Output stage
IBO5
14 : 14mm 2 : 5Vdc
G2 : driver 5Vdc RS422
9 : A,A/,B,B/,0,0/
(0 gated A&B)
80 000
max
G3 : PVC cable
8 wires
Example :
R020: radial
cable 2m
IB05 _
14 //
2
G2
9 // 10 000//
G3
R020
Available resolutions
: 50 60 100 120 125 127 150 180 200 240 250 256 300 314 360 375 400 500 512 600 720 750 762 768 800 927
1000 1024 1200 1250 1280 1440 1500 1800 2000 2048 2400 2500 3000 3600 4000 4096 5000
Interpolated available resolutions
: 1080 2560 2880 3072 4320 5120 5760 6000 7200 7500 8000 8192 9000 10000 10240 10800
12000 12500 12288 14400 15000 16000 16384 18000 20000 20480 24000 25000 28800 30000 32000 32768 36000 40000 40960
43200 48000 49152 50000 57600 60000 64000 65536 80000
NEVER CONNECT/DISCONNECT OR OPEN THE ENCODER WITH POWER ON IN DUST
ENVIRONMENTS
RESPECT THE MOUNTING TOLERANCES AND THE MECHANICAL RESTRICTIONS IN ORDER TO
REMAIN IN LINE WITH THE MAXIMUM SURFACE TEMPERATURE VALUE ALLOWED BY THE CLASS T4
REQUIREMENTS
LCIE 04 ATEX 6109 X /01 : CE certification of Type for the encoder :
Operating Temperature : -30°C to +70°C
The components of the device are intrinsically safe: they can be used in explosive atmospheres. The supply and output
circuits can only be connected to associated devices which are intrinsically safe and that are certified by type [ia]. These
devices must have electrical parameters that have a compatible supply with the above mentioned electronics, like BEI
barriers.
LCIE 04 ATEX 6155 X /01 : CE certification of Type for the encoder’s system (encoder associated with a BEI barrier) :
Operating temperature: barrier : -20°C to +40°C, encoder: -30°C to +70°C
The interconnecting cables have to be sufficiently protected against damage and have to be separated from the non
intrinsically safe circuits. They are described in the norm EN50020 paragraph 6.3, with the following characteristics
C=100pF/m and L=1.2µH/m, or with cables with other C and L values, With respect to the maximum authorized values:
Mines & Gases : Ca=3.9µF and L=0.4 mH
Dust : Ca=38.7µF and L=0.8mH
Made in FRANCE
Changes possible without further notice - Version 080919