Installation Instructions

CM2L40

23

Extend Limit Option
Internal set of dry contacts close when unit is fully extended.

Contact Rating: 30V AC or DC 1A max.

(See Figure 31) and (See Figure 38)

Figure 38

Retract Limit Option
Internal set of dry contacts close when unit is fully retracted.

Contact Rating: 30V AC or DC 1A max.

(See Figure 31) and (See Figure 39)

Figure 39

NOTE:

Multiple control features can be used at the same time with the exception of the "Voltage Sense" feature.

Example: IR or Serial control along with a momentary pushbutton for service and a discreet UP/DOWN wall switch for operation.

IMPORTANT ! :

When using multiple control features make sure ALL contacts are momentary and "Normally OPEN"

Connector and Switch Assignments

All Dipswitches are in the "OFF" position when shipped from factory.