CEMB USA K10_2 (E) User Manual
Page 4
I 0581 -
4
2
2a
GB
1.4 - Specifi cation
Weight (excluding adapter)
~ 80Kg.
Single-phase power supply
115 / 230 V 50/60 Hz
Protection class
IP 54
Max power consumption
0,8 Kw
Balancing speed
< 100 min
-1
Cycle time for average wheel (14 kg)
6-8 seconds
Max.resolution of measurement
1 gram
Position resolution
± 1.4 °
Average noise
< 70dB (A)
Rim-machine distance
0 - 265 mm
Rim width setting range
1.5” ÷ 20” or 40 ÷ 510 mm
Diameter setting range
10” ÷ 30” or 265 ÷ 765 mm
2 - HANDLING AND LIFTING
NOTE: DO NOT HOIST THE MACHINE USING DIFFERENT GRIPS
(See “Correct head disassembly” - paragraph:
GENERAL SAFETY REGULATIONS
)
3 - COMMISSIONING
3.1 - Anchoring
The machine can operate on any fl at non resilient fl oor.
Make sure that the machine rests solely on the three support points provided (fi g. 2a).
3.2 - Electrical connection
The machine is supplied with a single phase mains cable plus earth (ground).
The supply voltage (and mains frequency) is given on the machine nameplate. It cannot be changed.
Connection to the mains should always be made by expert personnel.
The machine should not be started up without proper earthing.
Connection to the mains should be through a slow acting safety switch rated at 3 A (230V) or 8 A (115V). See enclo-
sed layout.