CEMB USA K9 (A) User Manual
Page 8

I 0615 - 8
5
b
b
5a
5b
5c
5d
5e
POS. A
POS. B
GB
5 - INSTRUCTIONS FOR USE OF THE WHEEL BALANCER
5.1 - Using the gauge installed on the machine
5.1.1 - Data setting
►
►
For clamp weights, use the gauge in the top position A.
For adhesive weights, use the gauge as preferred in top position A
or bottom position B.
Note: Always use the round part of the striker plate
resting on the rim.
Indication of gauge in movement
5.2 - Automatic presetting
The machine automatically detects the correct balancing program for steel and aluminium rims (ALUS).
The counterweight position proposed may be changed using the two
/
buttons.
5.2.1 - Steel or aluminum wheel rims. Sprung counterweights
►
►
Pull out the gauge as far as the inner edge of the rim. Hold it in this
position until the symbol shown in Fig. 5d is displayed.
Indication of dimensions acquired
Return the gauge to rest position. The machine has automatically
detected DISTANCE + DIAMETER and goes to MANUAL WIDTH
SETTING.
- The nominal width is normally stamped
on the rim; if not, proceed to measure
dimension “b” with the calibre gauge
(supplied as standard).