beautypg.com

3 width sonar (option) – CEMB USA ER80 (B) User Manual

Page 18

background image

18

Calibro a riposo

Piano flangia

0 Sonar

A

Use and maintenance manual Rev. 10-2011

ENGLISH

Th

3.

e number 69 ± 3° appears on the left display .

Turn the gauge downward positioning the gauge rod

4.

in contact with the spindle shell as shown in the

images.

The nu

5.

mber 23 ± 3° should appear on the left

display. The calibration is already correct.

If not, press the

button holding the gauge: the

number 23 appears on the left display.
Return the gauge to rest position.

In the event of incorrect input in the diameter gauge calibration

function, press

to cancel it.

6.5.3 Width sonar (option)

Display the SETUP menu

P

1. ress

/

to view the width sonar

CALIBRATION

function.

Set with

2.

/

the distance in mm betwe

en the Sonar sensor (0 sonar) and t

he end of the

distance gauge (at rest).

A = Distance: Gauge at rest to

0 sonar

In the event of incorrect input in the width gauge calibration

function, press

to cancel it.

Setup