2 measurement result, 4 split function (unbalance resolution) – CEMB USA ER80 (B) User Manual

Page 13

background image

13

FI

FE

Use and maintenance manual Rev. 10-2011

ENGLISH

5.2 MEASUREMENT

RESULT

After performing a balancing spin, the unbalance values
are shown on the displays 1-2. The symbol shown on the
LED displays 3-4 and highlighted in the figure indicates the
correct angular position of the wheel in order to apply the
counterweights (12 o’clock) (for clip-on weights 6 o’clock
with laser indication for adhesive weights).
If the wheel clamp option is enabled (see

MENU

), the

wheel is automatically clamped in the correction position.

Pressing

the chuck can be locked/released in any

position to facilitate mounting the wheel (see

MENU

).

If the unbalance is within tolerance, 0 (zero) is displayed;
touching the display near any of the unbalance values,
you can read the values below the required tolerance
threshold.

5.3 EXACT POSITIONING OF THE ADHESIVE

WEIGHT BY MEANS OF THE GAUGE WITH
CLIPS

P

ress

if using the correction method with adhe-

sive weights on the inside of the rim

Fit the correction weight in the specific gauge seat with

the adhesive part facing upwards
Bring the wheel into correct angular position for the

plane to be corrected
If the wheel clamp option is enabled (see

MENU

),the wheel

is automatically clamped in the correction position.
withdraw the gauge until the correction plane indication

arrows turn green
If the buzzer is enabled (see

MENU

), the attainment

of the weight application distance is accompanied by

a beep.

If gauge locking is enabled (see MENU), the gauge
is automatically locked in position to prevent weight
application problems. To release the gauge, lower it
towards the spindle, or if this is not possible, move the
wheel.
Rotate the gauge until the correction weight adheres

to the rim
the fact that the weight application position is no longer

vertical is automatically compensated.

- INSIDE CORRECTION POSITION

- OUTSIDE CORRECTION POSITION

To cancel the function, press the

button again.

5.4

SPLIT FUNCTION

(unbalance

resolution)

The SPLIT function is used to position the adhesive weights
behind the wheel spokes (angle > 18°) so that they are no
longer visible (for alloy rims). Use this function in the ALU
or STATIC mode where the adhesive weight is applied to
the outer side of the rim.
Close the guard to perform an unbalance measurement
spin.

position the unbalance to be split in the correction

position in order to turn on the laser.

press and hold the button

until the laser points

to the spoke you wish to correct.

release the button

Turn th

e wheel in the direction of rotation of the unba-

lance indicated on the display until the second spoke
is in the position indicated by the laser and press

position t

he wheel as indicated by the LEDs. The un-

balance is indicated on the display

To return to the normal unbalance indication press

.

Use of the wheel balancer