5use of the wheel balancer – CEMB USA ER80 (B) User Manual
Page 11
11
a
b
Use and maintenance manual Rev. 10-2011
ENGLISH
5
Use of the wheel balancer
5.1
PRESETTING OF WHEEL DIMENSIONS
The balancing data is set by means of an “intelligent” au-
tomatic gauge; confi rmation of the measurement and the
position appear on the display. The round part of the gauge
must rest on the rim where the weight will be positioned.
While the gauge is moving the following appears:
when the measurement has been stored:
a) standard weights:
when only one measurement is
made, the machine interprets the presence of a rim with
clip-on weight correction
Use of the wheel balancer
b) adhesive weights:
make two successive measurements
on two correction planes inside the rim.
The balancing machine automatically interprets that the
correction will be made with adhesive weights and the
following appears:
For a different combination of the type or position of the
weights on the rim, press the matrix at points near the
rim symbol.
5.1.1 Automatic width
At the end of the automatic measurement of the distance
and diameter the following appears:
For large wheels (e.g. off-road vehicles, light trucks or wheels
protruding far out from the rim) press the
button to
switch from:
N.T. = NORMAL TYRE
L.T. = LIGHT TRUCK
Close the guard to perform an unbalance measurement
spin
.