beautypg.com

2 diameter gauge – CEMB USA ER80 (B) User Manual

Page 17

background image

17

Flange plane

Use and maintenance manual Rev. 10-2011

ENGLISH

Close the guard to perform a spin.

A

2. dd a standard weight of 60 g (2.00 oz) to the outer

side, in any position.

.

Close the guard to perform a spin.
Sh

3.

ift the standard weight from the outside to the

inside keeping the same position.

Close the guard to perform a spin.
Tu

4.

rn the wheel until the standard weight is at the top

(12

o’clock).

End of calibration.

5.

To cancel calibration at any time, press

.

6.5

AUTOMATIC GAUGES CALIBRATION

6.5.1 Rim distance gauge

Display the SETUP menu

P

1. ress

/

to view the rim distance

gauge CALIBRATION function.

Leave the distance gauge in rest position and press

2.

4. Move the distance gauge pusher in line with the

adapter surface and press

CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.

INDICATION

In the event of errors or faulty operation, the writing

r.P.:

ap

pears on the display : shift the gauge to the

rest position and repeat the calibration operation exactly

as described above. If the error persists, contact the

Technical Service Department. In the event of incorrect

input in the rim distance gauge calibration function, press

to cancel it.

6.5.2 Diameter gauge

E

Display the SETUP menu

P

1. ress

/

to view the diameter gauge

CALIBRATION

function.

m

Place the gauge rod on the spindle shell as shown

2.

in the figure and press

Setup