5 Use of the wheel balancer

5.1

PRESETTING OF WHEEL DIMENSIONS

The balancing data is set by means of an “intelligent” au-
tomatic gauge; the measurement confirmation is shown on
the display. The round part of the gauge must rest on the
rim where the weight will be positioned.

While the gauge is moving the following appears:

when the measurement has been stored:

Use of the wheel balancer

a) standard weights: when only one measurement is
made, the machine interprets the presence of a rim with

clip-on weight correction

b) adhesive weights: make two successive measurements

on two correction planes inside the rim.

The balancing machine automatically interprets that the
correction will be made with adhesive weights and the

following appears:

For a different combination of the type or position of the
weights on the rim, press the buttons near the rim symbol.

5.1.1 AWA

Enabling the AWA function, after the end of the automatic
distance and diameter measurement, the wheel balancer
suggests the most likely width value for the dimensions
just acquired. If necessary, change the width value by

pressing the

buttons, otherwise proceed

with normal balancing.

cAuTIoN

AWA

fuNcTIoN

does

NoT

WoRk

WITh

ANy

spAceRs

ANd

AdApTeRs

mouNTed

oN

The

flANGe

If the AWA function is disabled, the width value (b) must

be set with the

buttons.

The correct measurement is that which can be measured
with the compass gauge provided.