Use of the wheel balancer, 1 presetting of wheel dimensions, 2 modifying set dimensions – CEMB USA ER60 (A) User Manual
Page 9: 1 standard correction method, 5 use of the wheel balancer, 1 awa

9
a
b
b
Use and maintenance manual Rev. 09-2013
ENGLISH
5 Use of the wheel balancer
5.1
PRESETTING OF WHEEL DIMENSIONS
The balancing data is set by means of an “intelligent” au-
tomatic gauge; the measurement confirmation is shown on 
the display. The round part of the gauge must rest on the 
rim where the weight will be positioned.
While the gauge is moving the following appears:
when the measurement has been stored:
Use of the wheel balancer
a) standard weights: when only one measurement is 
made, the machine interprets the presence of a rim with 
clip-on weight correction
b) adhesive weights: make two successive measurements
on two correction planes inside the rim.
The balancing machine automatically interprets that the 
correction will be made with adhesive weights and the 
following appears:
For a different combination of the type or position of the 
weights on the rim, press the buttons near the rim symbol.
5.1.1 AWA
Enabling the AWA function, after the end of the automatic 
distance and diameter measurement, the wheel balancer 
suggests the most likely width value for the dimensions 
just acquired. If necessary, change the width value by 
pressing the
buttons, otherwise proceed
with normal balancing.
cAuTIoN
AWA
fuNcTIoN
does
NoT
WoRk
WITh
ANy
spAceRs
ANd
AdApTeRs
mouNTed
oN
The
flANGe
If the AWA function is disabled, the width value (b) must
be set with the
buttons.
The correct measurement is that which can be measured 
with the compass gauge provided.