2 diameter gauge – CEMB USA ER60 (A) User Manual
Page 16
16
Use and maintenance manual Rev. 09-2013
ENGLISH
6.5.2 Diameter gauge
E
Display the SETUP menu
1. Press
to view the diameter gauge
CALIBRATION function.
m
2. Place the gauge rod on the spindle shell as shown
in the figure and press
3. Turn the gauge downward positioning the gauge rod
in contact with the spindle sleeve as shown in the
figure
and press
CALIBRATION COMPLETE
▪ Return the gauge to rest position.
▪ The wheel balancer is ready for operation.
INdIcATIoN
In case of errors or malfunctions, the indication of the
same step [P.1] or [P2], always reappears on the display.
Move the gauge back into rest position and repeat the
calibration operation as described above; if the error
persists, contact Technical Service.
If erroneously accessing the diameter gauge calibration
function, press
to cancel it.
Setup