7 appendix b – wiring diagram 21.84, Appendix b – wiring diagram 21.84 – Castle TSM-21 Diagnostic Manual User Manual
Page 57
Castle Inc
TSM-21 Diagnostic Manual v2
Page 57 of 63
7 Appendix B – Wiring Diagram
21.84
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Drill Solenoid Valve
Clamp Solenoid Valve
Drill Stop Switch
(NC-Normally Closed)
Router Solenoid Valve
Foot Switch
(NO-Normally Open)
Router Stop Switch
(NC-Normally Closed)
15/16
EL-21G Circuit Board Term
inal Strip
16
15
Wood Sensor Switch
(NO-Normally Open)
13/14
11/12
9/10
7/8
5/6
3/4
D
Black
Power Switch
White
Green
Power
Cord
24 VAC
Transformer
120VAC
System Groun
d
F
oo
t Sw
itch
G
roun
d
Outlet
+24 VD
C