STEP #1:

The ‘UNDERLINE’ type cursor is located under
the length display whenever this screen is called up.
This indicates that this entry is capable of being
modified.

STEP #2:

Enter a new feed length; for instance...

1

.

253

inches.

Press the ‘

1

’ key, press the ‘

.

’ Key, press the ‘

2

’ key,

press the ‘

5

’ key, press the ‘

3

’ key, and press the

ENTER

’ key. The control will now take a moment

to clear the existing length value in its memory and
then "memorize" the new setting. The display
should now show the new feed length setting. The
maximum feed length is limited to 8,388,608
encoder counts or 999.750 inches.

4.2 PROGRAM A NEW

BATCH COUNT

STEP #1

Position the ‘UNDERLINE’ type cursor under
COUNT. Use the

key.

STEP #2

Enter a new desired batch count. For instance....
1000 pieces. Press the ‘

1

’, ‘

0

’, ‘

0

’, ‘

0

’, and ‘

ENTER

buttons. The control takes a moment to clear the
existing batch count setting in memory, and then
"memorizes" the new value. Enter a value of ‘

0

’ to

disable the batch counter. The display should now
show:

6

After the first Index/Part is made, the display
will show:

4.3 PROGRAM A NEW SPEED

FOR THE FEED

STEP#1:

Position the ‘UNDERLINE’ type cursor under
SPEED with the

key.

STEP #2:

Enter a new speed value, 60 inches per second is the
maximum speed setting. 1 inch per second is the
minimum speed setting.

We will use 50/inches per second as our
example... Press the ‘

5

’, ‘

0

’, and ‘

ENTER

’ buttons.

The control clears the existing value and inserts
50/seconds into its memory.

The display should now show the new setting:

These (3) parameters may be changed when the
running batch is stopped. All other feeder
parameters are locked out of the editing mode via

RUN/PROGRAM

’ switch located inside the

electrical enclosure on the panel.

LENGTH

00008.000

COUNT

100000

SPEED

0060/SEC

LENGTH

00001.253

COUNT

100000

SPEED

0060/SEC

LENGTH

00001.253

COUNT

100000

SPEED

0060/SEC

LENGTH

00001.253

COUNT

001000

SPEED

0060/SEC

LENGTH

00001.253

COUNT

001000

SPEED

0060/SEC

LENGTH

00001.253

COUNT

001000

SPEED

0060/SEC

000001 / 001000

LENGTH

00001.253

COUNT

001000

SPEED

0050/SEC

5. OPERATING THE FEED

NOTE:

It is very important to remember that the motor
on the Magnum Servo Feed System is only
for feeding material. It is not intended to be the
power source for a pull-through straightening
device, or the like. An adequate free loop must
be provided at all times. This will assure
consistent and accurate feeding.

5.1 PRIORITY MODE

The Magnum Servo Roll Feed has (2) modes of
automatic cycle starting. The Operator can