beautypg.com

1 program a new feed length, count, speed, 2 program a new batch count, 3 program a new speed for the feed – PA Industries Edge Servo Roll Feed SRF-100(for Serial Numbers 7610697 and higher) User Manual

Page 6

background image

• FETime: Following error time. FETime is the

maximum amount of time that the following error
limit may be exceeded before executing an
emergency stop.

• SYSTEM RESET:

This function clears all

parameters to the factory default conditions. No
program may be running,

RESET

must be active

(press and hold the ‘

POWER ON

’ button), and

the ‘

PROG/RUN

’ switch must be set to ‘

PROG

position. Pressing ‘

1

’ while the cursor is on the

SYSTEM RESET

line will result in a confirmation

screen being displayed. Pressing ‘

1

’ a second

time will reset the parameters to the factory
default values and the power-up screen will be
displayed. Pressing any other key than ‘

1

’ will

result in aborting the system reset.

4.1 PROGRAM A NEW FEED

LENGTH, COUNT, SPEED

To program a new feed pitch/length the program
must be stopped. This may be done by pressing the

POWER ON

’ or the ‘

CYCLE STOP

’ button

(if the press is running). Press the ‘

OPERATOR

button to view the following screen:

STEP #1:

The ‘UNDERLINE’ type cursor is located under
the length display whenever this screen is called up.
This indicates that this entry is capable of being
modified.

STEP #2:

Enter a new feed length; for instance...

1.253

inches.

Press the ‘

1

’ key, press the ‘

.

’ Key, press the ‘

2

’ key,

press the ‘

5

’ key, press the ‘

3

’ key, and press the

ENTER

’ key. The control will now take a moment

to clear the existing length value in its memory and
then "memorize" the new setting. The display
should now show the new feed length setting. The
maximum feed length is limited to 8,388,608
encoder counts or 4,015 inches.

6

4.2 PROGRAM A NEW

BATCH COUNT

STEP #1

Position the ‘UNDERLINE’ type cursor under
COUNT. Use the

key.

STEP #2

Enter a new desired batch count. For instance....
1000 pieces. Press the ‘

1

’, ‘

0

’, ‘

0

’, ‘

0

’, and ‘

ENTER

buttons. The control takes a moment to clear the
existing batch count setting in memory, and then
“memorizes” the new value. Enter a value of ‘0’ to
disable the batch counter. The display should now
show:

4.3 PROGRAM A NEW SPEED

FOR THE FEED

STEP#1:

Position the ‘UNDERLINE’ type cursor under
SPEED with the

key.

STEP #2:

Enter a new speed value, 100 inches per second
is the maximum speed setting. 1 inch per second is
the minimum speed setting.

We will use 50/inches per second as our
example... Press the ‘

5

’, ‘

0

’, and ‘

ENTER

’ buttons.

The control clears the existing value and inserts
50/seconds into its memory.

LENGTH

00001.253

COUNT

100000

SPEED

0062/SEC

LENGTH

00001.253

COUNT

100000

SPEED

0062/SEC

LENGTH

00001.253

COUNT

1000

SPEED

0062/SEC

LENGTH

00008.000

COUNT

100000

SPEED

0062/SEC

LENGTH

00001.253

COUNT

001000

SPEED

0062/SEC