Motec appendices 31, 20 amp outputs, 8 amp outputs – MoTeC PDM30 User Manual
Page 34: Inputs, Can input, Can output

MoTeC
Appendices
31
20 Amp Outputs
Number of 20 A outputs
PDM16
PDM32
PDM15
PDM30
8
8
8
8
Maximum output current
20 A continuous, 115 A transient (typical)
Over-current shutdown
Programmable in steps of 1 A
Protection
Short circuit and thermal overload
protection
Inductive load clamp voltage
–17 V (relative to Batt–)
Maximum inductive load
energy
1.5 J (junction temperature = 150 °C, load
current = 20 A)
8 Amp Outputs
Number of 8 A outputs
PDM16
PDM32
PDM15
PDM30
8
24
7
22
Maximum output current
8 A continuous, 60 A transient (typical)
Over-current shutdown
Programmable in steps of 1 A
Protection
Short circuit and thermal overload
protection
Inductive load clamp voltage
Output 9:
–0.7 V (relative to Batt–)
Other Outputs:
–42 V (relative to Batt+)
Maximum inductive load
energy
0.3 J (junction temperature = 150 °C, load
current = 20 A)
Inputs
Number of inputs
PDM16
PDM32
PDM15
PDM30
12
23
16
16
Pull-up resistor
10 kilo ohm to Batt+
Measurement
Range of 0 to 51 V, resolution 0.2 V
(8 bits)
Calibration
High and low trigger voltage, high and low
trigger times
CAN Input
Number of messages
4 messages, 8 bytes per message
CAN Output
Message rate
20 Hz