4.1 Lightning Protection
The Beacon incorporates protection against voltage surges (as induced by nearby
lightning strikes) by means of Gas Discharge Tubes (GDT’s).
Section 5: Maintenance and Troubleshooting
No regularly scheduled maintenance is required for the Beacon.
1-
Dialight warranties the light output of the Beacon to meet or exceed FAA
requirements for 5 years period (See Section 8, Dialight Warranty Statement).
LED Module replacement after 5 years is recommended to ensure FAA
compliance.
2-
General cleaning of the Dome Assembly is recommended after re-lamping with
regular glass cleaning solution, soapy water or any acrylic cleaning solutions. No
other cleaning solutions are recommended. Abrasive compounds will scratch the
Dome Assembly.
Table 1 Lists possible faults and repair procedures for the L-264 Beacon
Table 1 Troubleshooting
Symptom
Possible Cause
Corrective Action
Beacon does not light
No DC power
Damaged LED Module
Failed Power supply
Verify proper DC levels from
power source thru supply lines.
Replace defective LED Module.
See repair and replacement
procedures.
Replace power supply
Beacon does not flash
Refer to controller
documentation supplied