Dialight D564-A13-001 Vigilant L864 LED Based Red Medium Intensity Beacon User Manual
Page 9

Document No.
9100-127-1733-99 Rev A
June 19, 2013
_____________________________________________________________________
_____________________________________________________________________________
Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727
Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com
9 of 14
Figure 5 – Beacon in Open Position
Step 5
Rotate the lamp downwards to approximately 10 degrees from the
closed position. The key should line up with the keyway on the hinge and
allow for the lamp to be pulled off of its pins.
Figure 6 – Lamp Install/Removal Position
Step 6 Slide the new lamp onto the pins to line it up. Rotate it to approximately
10 degrees from closed to again line up the keyway. Push the light
engine past the key until it clears and than rotate it back to the open
position.
Step 7
Reconnect the line and neutral wires to the terminal block, followed by
the grounding strap.
Step 8
Rotate the lamp down to the closed position and secure the two latches
to complete installation. Apply power to ensure the beacon lights up
correctly.