General Information

The FERGUSON Torque Limiter is a high quality, precision mechanism. To gain the optimum benefits, the

guidelines described in this manual should be used.

Safety

Read and follow all Warnings and Cautions prior to any service or repair.

1. Read your Overload Clutch Installation-Operation Instructions thoroughly before operating the unit,

for your safety and the protection of your unit.

2. FERGUSON Overload Clutches are designed to protect the Index Drive only and will not protect

against bodily injury.

3. Double check to be sure the power is off and cannot be turned on while working on the equipment.

4. Use extreme caution with jammed or unbalanced loads, which when cleared may set the machine in

motion.

5. Keep all objects such as hands, clothing, and tools away from rotating or moving parts.

6. Use safety glasses or equivalent to protect your eyes.

7. Dowel pins and mounting screws must not protrude from the drive plate or driven member, as the

clutch could become a solid coupling.

8. High humidity, contaminants, or wash down applications may cause rust within the clutch, resulting in

operational failure. Lubricate every six months or more frequently as the application requires.

9. The FERGUSON clutch is not a "FAIL SAFE" device and cannot be used on "overhauling" or

"holding" load applications.

10. When using chain drives, incorporate an idler sprocket to eliminate any slack.

NOTE: The above list includes major safety points to be observed, but should not be
considered as limiting in safety precautions to be followed.

NOTE: In the event the unit is damaged, contact Industrial Motion Control’s Wheeling
factory or your local representative, for replacement.

Operating Environment

This product is intended to operate in a clean environment. Excessive coolant, chips, dust, dirt or debris

can adversely affect its performance and life. If this device does operate in a dirty environment periodic

cleaning must be practiced and careful inspection of seals and accessories is necessary.