SECTION 7: Troubleshooting

TROUBLESHOOTING GUIDE

Symptom

Cause

Solution

Backlash at output shaft

Worn/damaged followers

Replace

(in dwell)

Tight Stations

Bent cam followers

Replace; inspect holes in roller

(torque required to rotate

gear shaft

cam shaft through tight

station is more than 1

1

/

2

times the loose station)

Pitting of cam follower

Incorrect oil

Replace cam followers and fill

outer race/cam track surface

unit with correct oil

Fine magnetic metallic particles

Steel and iron worn from

Flush out when replacing oil

in oil; appear bronze color

bearing roller ends and cages

when in oil

and cams surface (this is a

normal condition)

REDUCER:

Excessive Backlash

A. End play in worm shaft

Contact Technical Services at

800-645-5207 or 847-459-5200.

B. Loose gear on camshaft.

Contact Technical Services at

800-645-5207 or 847-459-5200.

Overheating in Excess of 210°F

A. Worm-shaft bearings

Contact Technical Services at

pre-load.

800-645-5207 or 847-459-5200.

B. Incorrect alignment of

Contact Technical Services at

worm and gear.

800-645-5207 or 847-459-5200.

C. Excessive worm speed.

Reduce worm speed.