BatteryMINDer 24041-AA-S1 User Manual
Page 32
Rev. F-103007
P/N VDC24041AA-S1-MNL
BatteryMINDer
®
Model 24041-AA-S1
Page 32
DETAILED SPECIFICATIONS - VDC Model No. 24041-AA-S1 (con’t.)
Battery sulfation check period (After absorption charge is finished): 10 minutes
Unloaded output voltage when battery is disconnected: 0.5 Vdc (max.)
Output short-circuit current when battery disconnected: 5mA dc (max.)
Battery flow back current (to the charger) when connected to 24V battery, AC Power disconnected:
30 (max.) mA dc
All LED indicators will shut off if AC power is disconnected for 5 Minutes
Full time Desulfation output pulse current control Ip-p ±3 Adc
Full time Desulfation output PWM* frequency 100 ±10Hz
Full time Desulfation duty 0.3%
*Pulse Width Modulated
Temperature Compensation (with ABS-124 Battery Temperature Sensor)
detailed on pages 21 -24.
LED Indicator functions
Tables 5 & 6
RED
AVIATION
ON
GREEN
4A
ON
TABLE 5
TABLE 6