beautypg.com

BatteryMINDer 24041-AA-S1 User Manual

Page 23

background image

Rev. F-103007

P/N VDC24041AA-S1-MNL

BatteryMINDer

®

Model 24041-AA-S1

Page 23

The chart below shows the need to regulate the output voltage of the charger to ensure against over or
under charging your battery over a wide range of temperatures. Using your At-the-Battery Sensor will
accomplish this better than any other known method.

**

Values shown in

RED

are based on information supplied by Concorde Battery Co., effective 12-27-06. Values for batteries

manufactured by other aviation battery companies are believed to be comparable. We

strongly recommend checking with the ap-

propriate dealer or battery manufacturer to be certain.

VDC, nor its resellers, will be responsible for any aviation type battery

found to be damaged by any of our Aviation Calibrated (-AA) chargers, as we cannot confirm whether or not the user
correctly selected the required battery type or used and correctly installed the Temperature Sensor type ABS-124.

Aviation Charge and Float Voltages at Various Temperature Ranges**

Temp °F

Optimum Charge

Optimum Float

Temp °C

≥120

26.80

24.90

≥49

110 – 120

27.20

25.10

43 – 49

100 -110

27.40

25.30

38 – 43

90 – 100

27.60

25.50

32 – 38

80 – 90

27.80

25.70

27 – 32

70 – 80

28.20**

26.10**

21 – 27

60 – 70

28.50

26.60

16 - 21

50 – 60

28.80

27.00

10 - 16

40 – 50

29.20

27.40

4 - 10

≤40

29.80

27.80

≤4