Page 23
The chart below shows the need to regulate the output voltage of the charger to ensure against over or
under charging your battery over a wide range of temperatures. Using your At-the-Battery Sensor will
accomplish this better than any other known method.
**
Values shown in
RED
are based on information supplied by Concorde Battery Co., effective 12-27-06. Values for batteries
manufactured by other aviation battery companies are believed to be comparable. We
strongly recommend checking with the ap-
propriate dealer or battery manufacturer to be certain.
VDC, nor its resellers, will be responsible for any aviation type battery
found to be damaged by any of our Aviation Calibrated (-AA) chargers, as we cannot confirm whether or not the user
correctly selected the required battery type or used and correctly installed the Temperature Sensor type ABS-124.
Aviation Charge and Float Voltages at Various Temperature Ranges**
Temp °F
Optimum Charge
Optimum Float
Temp °C
≥120
26.80
24.90
≥49
110 – 120
27.20
25.10
43 – 49
100 -110
27.40
25.30
38 – 43
90 – 100
27.60
25.50
32 – 38
80 – 90
27.80
25.70
27 – 32
70 – 80
28.20**
26.10**
21 – 27
60 – 70
28.50
26.60
16 - 21
50 – 60
28.80
27.00
10 - 16
40 – 50
29.20
27.40
4 - 10
≤40
29.80
27.80
≤4